Julian G4ILO did an interesting experiment with WSPR
He used a power of 20 mW and 1 mW and was heard over large distances.
I made a table of the spots with both 1 mW and 20 mW.
I left out the few spots that were made with 50 mW.

The table below shows an interesting phenomena.
When 20 mW is used, the  calculated lowest possible power is 20 mW or less.
When 1 mW is used the calculated possible power is 1 mW or less.



The Lowest Possible Power is calculated from the used power and the SNR.
The SNR for a solid copy with WSPR is -29 dB.
When a signal is received with a SNR of -19 dB, this signal is 10 dB stronger, 
so the power could be 10 dB reduced and still be solid copy, but then with a SNR of -29 dB.
The Lowest Possible Power is 20/10 = 2 mW 
22 Spots were made with a Lowest Possible Power of 2 mW.

The tables below show the distance, the receiving station and the power that was used.


3 opmerkingen:

  1. Hallo Bert, nog even en het gaat over microW. Wat....nog even en je hoeft alleen maar te denken aan een WSPR signaal en de frequentie en het vermogen van de gedachte alleen al is genoeg om gespot te worden ;-). 73, Bas

    BeantwoordenVerwijderen
    Reacties
    1. Mij kwam de gedachte op om met 0 watt te gaan zenden. Kijken hoever je komt. ;-)

      Verwijderen
    2. Hallo Bas en Paul,
      Elke decade (factor 10) is verdeeld in één stap van 4 dB en twee stappen van 3 dB. Samen 10 dB
      Van 5mW naar 2mW is een factor 2,5. Dus 4 dB in vermogen.
      Dat geldt ook voor 0,5 naar 0, 2, van 0,05 naar 0,02 enz. Dit zijn ook stappen van een factor 2,5.
      De rest van de stappen is een factor 2. Dit is 3 dB in vermogen.
      Met elke toegevoegde decade (10 dB) wordt het vermogen 10 keer zo klein, maar nooit nul